I. Lights
Chamber lights won't come on or
are dim. (Unit is otherwise
functioning normally)
J. Material/Unload Error
1. Material Error
Filament error
2. Material Error
Filament blocked
3. Material Error
Carrier invalid
4. Material Error
Filament broken
5. Load Error
Filament blocked
6. Load Error
Purge failed
7. Unload Error
Unload failed
8. Filament does not reach
filament present switch.
1. Check and reseat connectors to the light bar.
2. Swap light bars to determine whether bad
light bar or bad cable.
3. Lights are burnt out - replace light bars.
4. Light bar cable is bad - replace cable.
1. Remove the carrier and verify material is
coming out of the material guide.
2. Verify material pulls freely from the carrier.
3. Verify the material tubes are free of material
4. Reload material.
1. Remove carrier and verify material pulls freely
from carrier.
2. Verify the material tubes are free of material.
3. Reload material.
1. Remove carrier and verify it is not empty.
2. Replace material spool.
1. Remove the carrier and verify material is
coming out of the material guide.
2. Verify material pulls freely from the carrier.
3. Verify the material tubes are free of material
1. Remove the carrier and verify material is
coming out of the material guide.
2. Verify material pulls freely from the carrier.
3. Verify the material tubes are free of material
1. Remove the carrier and verify material is
coming out of the material guide.
2. Verify material pulls freely from the carrier.
3. Verify the material tubes are free of material
4. Check for and clear any excess material build
up around the tips.
5. Material may be jammed in head. See
"Material Jam" on page 80..
1. Remove the carrier and verify the material
tubes are free of material.
1. Filament is being cut off too long at carrier.
Less than 1/4" should be exposed
2. Filament slipped into guide tube. Make sure
filament extends to the end of the guide tube.
3. High pull force spool, refer to "filament slips
at head" under LOE section.
4. Possible bad drive motor, replace material
bay.