Device Overview
2.4 Wiring Principle
Circuit principle for version A, parallel connection with 12-pulse infeed, motor with separate winding
systems
Figure 2-8
32
PE
~
~
=
-W001
DCPS
DCNS
-W002
=
~
~
PE
M
1U2
1V2
~
1W2
Circuit principle for version A, parallel connection, 12-pulse infeed, connected to one
motor with separate winding systems.
PE
~
~
=
DCPS
DCNS
=
~
~
PE
2U2
2V2
2W2
PE
PE
Converter cabinet units
Operating Instructions, 03/2012, A5E03263466A