(2) Output monitor switching by parallel input
On the operation screen, select "MAIN-COND" ->
"SYS-CND" -> "I/O CONDITIONS" in that order.
Move the cursor to the "
line using up/down arrow keys and press the SET
key. Select "CHNG-IMG-OUT-CAM" on the popup
menu that is displayed and then press the SET
key.
Every time the X7 signal is turned from OFF to
ON, the selected camera display will be changed.
CAM1
CAM2
whole screen
whole screen
*CAM1&2(VERT) divided screen
The display example of the operation screen is
the same as in section (1).
Setting the Operating and System Conditions
PARALLEL INP X7"
CAM1&2(HORIZ)
divided screen
2-3
I/O CONDITION SCREEN COND SAVE
1MEAS INP I/F
PARALLEL+SERIAL+USB
2OUT I/F(PARAL.)
NO
3MANL TYPE CHNG NO
4PARALLEL INP X6 EXT-INP
5PARALLEL INP X7 CHNG-IMG-OUT-CAM
6STROBE OUT
NO
7'READY'ON
CAPTURE COMPLETE
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
COLOR F C1 BRT
2
EXT-INP
CHNG-IMG-OUT-CAM
CAM-MEAS