When an abnormal termination code (other than 00
Termi-
nation
code
(H)
01 The specified processing code does not exist.
The wrong number of data items was specified
02
in the text.
03 The text data is outside the acceptable range.
04 The results of the check sums are not identical.
The header code (:) was not attached to the
05
head of the communication command.
06 An asynchronous error has occurred.
The communication command contains an
07
improper number of data items.
An error response has been returned from the
08
programmable controller. (Communications are
performed normally.)
A time-out has occurred during communication
09
through the computer link.
Start address error (larger than the end
0A
address)
10 SDRAM error
11 Flash memory error
No camera connected to the camera 1
12
connector.
No camera connected to the camera 2
13
connector.
14 VRAM error has occurred.
18 Flash ROM delete error
19 Flash ROM write error
1A Flash ROM verify error
The measurement conditions for the specified
20
object type have not been set.
The setting area is larger than the screen, due
21
to positional correction.
Correction after binary conversion: The
22
illuminance monitor function (system) has not
been set.
Correction after binary conversion: The
23
threshold range has exceeded the specified
range.
24 No edge detection
25 A reference image has not been registered
26 Number of labels exceeds the specified amount
27 No setting for number of image lines
28 "0" subtraction error (numeric calculation)
) is received, take the following measures.
(H)
Cause
24-3
Remedy
Check the processing code.
Check the number of data items in the text.
Check the text setting range.
-
Check the check sums.
-
Check the communication environment
for problems such as electric noise, which
may come in on the communication line.
Check whether the header code was attached
to the head of the communication command.
- Check the communication environment for
problems such as electric noise, which may
come in on the communication line.
Check the number of data items in the
communication command.
The error code is contained in the evaluation
result area, and the error code is displayed on
the monitor. Take the proper measures
according to the error code (different models
use different codes).
-
Make sure the power supply of the
programmable controller and check the
connections of the cables.
-
Check the communication conditions and
computer link settings.
Check the address.
Replace the IV-C35M itself.
Connect a camera.
Replace the IV-C35M itself.
Check the abnormal setting.