[1] Set the register conditions for a gray search

This paragraph describes setting procedures when the mode (see page 13-3) is set to "1-PNT SCH."
REGISTER NO.
Enter a register number. When making color
positional measurement, you can select any
register from 0 to 7 (a total of 8 registers).
COLOR DETECT
Select a reference color for color extraction from
the already registered colors (when more than
two colors are registered).
MEAS SHAPE(MDL0)
Specify reference image area and search area. Enter coordinates for upper left and lower right
corners. Inside the rectangle specified by these entries is the range of each area.
REFIMG ARE
Move the cursor to "
and press the SET key. When the SET item is
highlighted, press the SET key again to bring
up the setting screen. Specify upper left and
lower right corners of the rectangle. The setting
procedures are the same as those used for
positional deviation measurement.
See page 4-6.
REFIMG ARE(MDL0)"
13-5
Color Positional Measurement
REG CND
SCREEN COND SAVE DETAIL
1REGISTER NO.
0 (0 7)
2COLOR DETECT
0 (0 7)
3MEAS SHAPE (MDL 0)
RECTANGLE
4REFIMG ARE (MDL 0)
SET (224, 208) (287, 271)
5SEARCH ARE
(MDL 0)
SET (216, 200) (295, 279)
6REFIMG
(MDL 0)
000 (000 000)
7DETECT CRD
(MDL 0)
CENTER (255, 239)
=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
RECTANGLE
RESET
RETURN
MDL 0
1UP. L
(224, 208)
2LO. R
(287, 271)
3MOVE
4REFFERENCE IMG
=MOVE ESC=BACK SEL=CHNG IMG TRG=FUNC
COLOR F C1 BRT
REFERENCE IMG
DETECT CRD
13
COLOR F C1 BRT
Reference image area
Search area
X:224 Y:208