Set the evaluation conditions
How to move to the evaluation condition setting screen
There are two methods for getting to the evaluation condition setting screen.
1) Select "COND" in the upper function menu on
the MEAS COND (or REG COND) screen and
press the SET key. Select "EVALUATION" on
the popup menu to go to the EVALUAT COND
screen.
2) Move the cursor to the "EVALUATION COND"
item on the menu tree screen and press the SET
key.
The "EVALUAT COND" (evaluation conditions)
screen will appear.
For details about the evaluation conditions,
see page 3-28.
Color Positional Measurement
REG CND
SCREEN COND SAVE
1REGISTER NO.
2COLOR DETECT
3MEAS SHAPE (MDL 0)
4REFIMG ARE (MDL 0)
5SEARCH ARE
(MDL 0)
=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
EVALUAT COND
SCREEN COND SAVE EDIT SEL
1REGISTER NO.
0 (0 7)
2CONDITION SET
AUTO (±10%)
3X COORD. (MDL0)
000. 0
4Y COORD. (MDL0)
000. 0
5x DEVIATE (MDL0)
-511.0
6y DEVIATE (MDL0)
-479.0
7MATCH LVL (MDL0)
-10000
8TEST
=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
13-9
COLOR F C1 BRT
0 (0 7)
REG-COND (S)
0 (0 7)
REG-COND (E)
RECTANGLE
EVALUATION
SET (224, 208) (287, 271)
NUM-CALC
SET (216, 200) (295, 279)
OUT
1REGISTER NO.
2CONDITION SET
3X COORD.
(MDL0)
4Y COORD.
(MDL0)
5x DEVIATE
(MDL0)
6y DEVIATE
(MDL0)
7MATCH LVL (MDL0)
8TEST
COLOR F C1 BRT
[TEST RESULT]
[OUTPUT]
511.0
X0=
NO
479.0
Y0=
NO
+511.0
x0=
NO
+479.0
y0=
NO
+10000
M0=
NO
EXEC (WITH-POSI. ADJ WITHOUT-POSI. ADJ)