Mitsubishi Electric FR-A700 Instruction Manual page 77

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Wiring
● Torque control
Standard motor with encoder (SF-JR),
5V differential line driver
Three-phase
Forward rotation start
Reverse rotation startf
Contact input common
Frequency
command
Frequency
setting
potentiometer
1/2 W, 1kΩ
Torque
command
(±10 V)
Tab. 3-17: Torque control
The pin number differs according to the encoder used. Speed control and torque control are
properly performed even without connecting Z phase.
Connect the encoder so that there is no looseness between the motor and motor shaft.
Speed ratio should be 1:1.
Earth (Ground) the shielded cable of the encoder cable to the enclosure with a P clip, etc.
(Refer to page 3-41.)
For the complementary, set the terminating resistor selection switch to off position. (Refer
to page 3-35.)
A separate power supply of 5V/12V/15V/24V is necessary according to the encoder power
specification. When performing orientation control together, an encoder and power supply
can be shared.
For terminal compatibility of the FR-JCBL and FR-A7AP, refer to page 3-37.
NOTE
The figure above shows the connection when using sink logic.
FR-A700 EC
Inverter
MCCB
AC power
supply
Differential
Complimentary
Terminating
resistor
ON
OFF
Connection of motor with encoder (vector control)
Vector control dedicated motor,
12V complimentary
SF-JR motor with
encoder
M
3~
Earth
Encoder
5V DC power supply
I001445E
Inverter
Earth
Differential
Compli-
mentary
Terminating
resistor
ON
OFF
5V DC power supply
M
3~
Encoder
I001446E
3 - 39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a740 ecFr-a700 ec

Table of Contents