Motor brake and stop operation
Fig. 6-108: Connection example
The input signal terminal used differs according to the Pr. 180 to Pr. 189 settings.
Fig. 6-109: Switchng to the stop-on contact control mode
6 - 258
MCCB
Power supply
Forward rotation command
High-speed operation command
Middle-speed operation command
Stop-on contact selection 0
Stop-on contact selection 1
Pr. 4
Pr. 5
Pr. 6
* Goes into stop-on-contact control when both RL and RT
switch on. RL and RT may be switched on in any order
with any time difference.
(a): Acceleration time (Pr. 7)
(b): Deceleration time (Pr. 8)
(c): Second deceleration time (Pr. 44/Pr. 45)
Normal mode
Stop-on-contact control mode
ON
OFF
ON
OFF
ON
OFF
ON
Parameter
MC
Mechanical
brake
Motor
Time
I001568E
I001569E