Mitsubishi Electric FR-A700 Instruction Manual page 391

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter
Adjustment of shortest acceleration/deceleration mode (Pr. 61 to Pr. 63)
By setting the adjustment parameters Pr. 61 and Pr. 63, the application range can be made
wider.
Pr. No.
61
62
63
Tab. 6-43: Adjustment parameter setting
NOTES
Pr. 61 to Pr. 63 are invalid when real sensorless vector control or vector control is selected in
the shortest acceleration/deceleration mode.
Under advanced magnetic flux vector control, real sensorless vector control or vector control
the elevator mode can not be activated.
Since the Pr. 61 to Pr. 63 settings automatically return to the initial value (9999) if the Pr. 292
setting is changed, set Pr. 292 first when you need to set Pr. 61 to Pr. 63.
FR-A700 EC
Name
Setting Range
01800 or
less
02160 or
Reference current
more
9999 (initial value)
Reference value at
acceleration
Reference value at
deceleration
9999 (initial value)
Description
For example, when the motor and inverter are different
0–500A
in capacity, setthe rated motor current value.
Shortest acceleration/deceleration: Set reference cur-
rent (A) of the stall prevention operation level during
acceleration/deceleration.
0–3600A
Optimum acceleration/deceleration: Set reference cur-
rent (A) of the optimum current during acceleration/
deceleration.
The rated inverter current is defined as reference.
Set when it is desired to change the reference level of
acceleration and deceleration.
Shortest acceleration/deceleration: Set the stall pre-
vention operation level (ratio to the current value of Pr.
0–200%
61) during acceleration/deceleration.
Shortest acceleration/deceleration: Set the optimum
current level (ratio to the current value of Pr. 61) dur-
ing acceleration/deceleration.
Shortest acceleration/deceleration: The 150% value
during shortest acceleration/deceleration is judged as
the stall prevention operation level.
Optimum acceleration/deceleration: 100% is the opti-
mum value
Acceleration and deceleration
6 - 211

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a740 ecFr-a700 ec

Table of Contents