Parameter
Fig. 6-191: Signal adjustment of terminal 1
Fig. 6-192: Signal adjustment of terminal 4
There are the following three methods to adjust the torque setting voltage (current) bias and
gain.
● Method to adjust any point without application of voltage (current) to across terminals 1-5
(4-5). (Refer to page 6-397)
● Method to adjust any point without application of voltage (current) to across terminals 1-5
(4-5). (Refer to page 6-398)
● Method to adjust torque only without adjustment of voltage (current). (Refer to page 6-399).
NOTE
When voltage/current input specifications were switched using Pr. 73 and Pr. 267, perform
calibration without fail.
FR-A700 EC
Frequency/torque setting by analog input (terminals 1, 2 and 4)
400
150
(−5 V)
(−10V)
Bias
−100 %
C16 (Pr. 919)
Calibration example of terminal 1
400
150
Bias
C38
(Pr. 932)
0
20
0
4
C39 (Pr. 932)
Calibration example of terminal 4
Initial
value
0
Torque setting
0
signal
0
C17 (Pr. 919)
−150 %
Gain
C40
(Pr. 933)
Initial
value
Torque setting
100 %
20 mA
signal
C41 (Pr. 933)
Gain
C18 (Pr. 920)
100 %
5 V
10 V
C19 (Pr. 920)
I001615E