Communication operation and setting
● Parameter
Parameter Register Parameter Name
0–999
C2 (902)
C3 (902)
125 (903)
C4 (903)
C5 (904)
C6 (904)
126 (905)
C7 (905)
C8 (930)
C9 (930)
C10 (931)
C11 (931)
C12 (917)
C13 (917)
C14 (918)
C15 (918)
C16 (919)
Tab. 6-164: Parameter
6 - 482
Refer to the parameter list
41000–
(Tab. 6-1) for the parameter
41999
names.
Terminal 2 frequency setting bias
41902
(frequency)
Terminal 2 frequency setting bias
42092
(analog value)
Terminal 2 frequency setting bias
43902
(terminal analog value)
Terminal 2 frequency setting gain
41903
(frequency)
Terminal 2 frequency setting gain
42093
(analog value)
Terminal 2 frequency setting gain
43903
(terminal analog value)
Terminal 4 frequency setting bias
41904
(frequency)
Terminal 4 frequency setting bias
42094
(analog value)
Terminal 4 frequency setting bias
43904
(terminal analog value)
Terminal 4 frequency setting gain
41905
(frequency)
Terminal 4 frequency setting gain
42095
(analog value)
Terminal 4 frequency setting gain
43905
(terminal analog value)
41930
Current output bias signal
42120
Current output bias current
41931
Current output gain signal
42121
Current output gain current
41917
Terminal 1 bias frequency (speed)
42107
Terminal 1 bias (speed)
Terminal 1 bias (speed)
43917
(terminal analog value)
41918
Terminal 1 gain frequency (speed)
42108
Terminal 1 gain (speed)
Terminal 1 gain (speed)
43918
(terminal analog value)
Terminal 1 bias command
41919
(torque/magnetic flux)
Read/write
Remarks
The parameter number +
Read/write
41000 is the register number.
Read/write
The analog value (%) set to
Read/write
C3 (902) is read.
The analog value (%) of the
Read
voltage (current) applied to the
terminal 2 is read.
Read/write
The analog value (%) set to
Read/write
C4 (903) is read.
The analog value (%) of the
Read
voltage (current) applied to the
terminal 2 is read.
Read/write
The analog value (%) set to
Read/write
C6 (904) is read.
The analog value (%) of the
Read
current (voltage) applied to the
terminal 4 is read.
Read/write
The analog value (%) set to
Read/write
C7 (905) is read.
The analog value (%) of the
Read
current (voltage) applied to the
terminal 4 is read.
Read/write
Read/write
Read/write
Read/write
Read/write
Analog value (%) set in C13
Read/write
(917) is read.
Analog value (%) of the
Read
voltage applied to terminal 1 is
read.
Read/write
Analog value (%) set in C15
Read/write
(918) is read.
Analog value (%) of the
Read
voltage applied to terminal 1 is
read.
Read/write
Parameter