Mitsubishi Electric MELSERVO-J2 Series Instruction Manual page 183

Servo amplifier
Table of Contents

Advertisement

8. COMMUNICATION FUNCTIONS
(5) Dwell time read
Read the dwell time of the point table.
(a) Transmission
Transmit command [6][0] and any of data No. [0][1] to [0][F] corresponding to the point table to be
read. Refer to Section 8.11.1.
(b) Reply
The slave station sends back the dwell time of the requested point table.
0
When the enable/disable setting is read disable, ignore the data part and process it as unreadable.
(6) Auxiliary function read
Read the auxiliary function of the point table.
(a) Transmission
Transmit command [6][4] and any of data No. [0][1] to [0][F] corresponding to the point table to be
read. Refer to Section 8.11.1.
(b) Reply
The slave station sends back the auxiliary function of the requested point table.
0
When the enable/disable setting is read disable, ignore the data part and process it as unreadable.
Downloaded from
ManualsNet.com
Hexadecimal data
0
Display type
0: Used unchanged in hexadecimal
1: Conversion into decimal required
Parameter write type
0: Valid after write
1: Valid when power is switched on again after write
Read enable/disable
0: Read enable
1: Read disable
Hexadecimal data
0
Display type
0: Used unchanged in hexadecimal
1: Conversion into decimal required
Parameter write type
0: Valid after write
1: Valid when power is switched on again after write
Read enable/disable
0: Read enable
1: Read disable