Class No. Symbol
46
*LMP
47
*LMN Software limit
48
49
50
*LPP
51
52
*LNP
53
54
55
56
57
58
59
60
61
62
63
64
65
66
Downloaded from
ManualsNet.com
Name and Function
Software limit
Used to set the address increment side software stroke limit. The
software limit is made invalid if this value is the same as in
"software limit
".
Set the same sign to parameters No.46 and 47. Setting of different
signs will result in a parameter error.
Set address:
Upper 3
digits
Used to set the address decrement side software stroke limit. The
software limit is made invalid if this value is the same as in
"software limit ".
Set the same sign to parameters No.48 and 49. Setting of different
signs will result in a parameter error.
Set address:
Upper 3
digits
Position range output address
Used to set the address increment side position range output
address. Set the same sign to parameters No.50 and 51. Setting of
different signs will result in a parameter error.
Set address:
Upper 3
digits
Position range output address
Used to set the address decrement side position range output
address. Set the same sign to parameters No.52 and 53. Setting of
different signs will result in a parameter error.
Set address:
Upper 3
digits
For manufacturer setting
The setting is automatically changed.
For manufacturer setting
Never change the setting.
search engine
Lower 3
digits
Parameter No. 47
Parameter No. 46
Lower 3
digits
Parameter No. 49
Parameter No. 48
Lower 3
digits
Parameter No. 51
Parameter No. 50
Lower 3
digits
Parameter No. 53
Parameter No. 52
5 - 12
Initial
Setting
Unit
Reference
Value
Range
0
10
999999
Section
STM
m
to
5.2.8
999999
0
10
999999
Section
STM
m
to
5.2.8
999999
0
10
999999
STM
m
to
999999
0
10
999999
STM
m
to
999999
0001
0009
080A
0706
020B
0504
0002
0000
0005
0304