5. PARAMETERS

5.1.2 Lists

For details of the parameters, refer to the corresponding items.
(1) Item list
Class
No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Downloaded from
ManualsNet.com
POINT
For any parameter whose symbol is preceded by*, set the parameter
value and switch power off once, then switch it on again to make that
parameter setting valid.
Symbol
Name and Function
*STY
Command system, regenerative brake option selection
*FTY
Feeding function selection
*OP1
Function selection 1
AUT
Auto tuning
*CMX
Electronic gear numerator
*CDV
Electronic gear denominator
INP
In-position range
PG1
Position loop gain 1
*ZTY
Home position return type
*ZRF
Home position return speed
CRF
Creep speed
ZST
Home position shift distance
CRP
Rough match output range
JOG
Jog speed
*STC
S-pattern acceleration/deceleration time constant
*SNO
Station number setting
*BPS
Communication baudrate
MOD
Analog monitor output
*DMD
Status display selection, alarm history clear
*BLK
Parameter write inhibit
search engine
Initial Value
0000
0000
0002
0102
0010
0000
0100
0000
0000
5 - 2
Customer
Unit
Setting
1
1
100
pulse
36
rad/s
500
r/min
10
r/min
m
0
m
0
10
STM
100
r/min
0
ms
0
station