Parameter Mode - Mitsubishi Electric MELSERVO-J2 Series Instruction Manual

Servo amplifier
Table of Contents

Advertisement

7. DISPLAY AND OPERATION

7.6 Parameter mode

Change the parameter settings when:
The regenerative brake option is used;
The number of pulse per servo motor revolution is changed
The machine mounted with the servo motor hunts or operational performance is further improved.
The parameter whose abbreviation is marked * is made valid by switching power off, then on after
changing its setting. (Refer to Section 5.2.1.)
(1) Operation example
1) 4-digit parameter
The following example shows the operation procedure performed after power-on to change the home
position setting method (Parameter No.8) into the data setting type.
To shift to the next parameter, press the "UP" or "DOWN" button.
When changing the parameter No.8 (home position return type) setting, change its set value, then
switch power off once and switch it on again to make the new value valid.
Downloaded from
ManualsNet.com
Press
four times. Select parameter No.8 with
MODE
The parameter number is displayed.
Press
UP
Press
twice.
SET
The set value of the specified parameter number flickers.
Press
twice.
UP
During flickering, the set value can be changed.
Use
UP
(
2: Data setting type)
Press
to enter.
SET
search engine
or
to change the number.
DOWN
or
.
DOWN
7 - 8
or
.
UP
DOWN

Advertisement