Change In Logic Of Interrupt Input Signal (Dvit Instruction - Mitsubishi Electric FX3S Series User Manual

Hide thumbs Also See for FX3S Series:
Table of Contents

Advertisement

FX
/FX
/FX
3S
3G
3GC
Built-in Positioning Functions
*2.
*3.
*4.
Example program:
The following program specifies the interrupt input signal for each pulse output destination device as shown in
the following table.
Pulse output
destination device
*5.
4.3.8

Change in Logic of interrupt input Signal (DVIT Instruction)

Turn the "Interrupt signal logic reverse" relay ON or OFF to specify the logic of the interrupt input signal of the
interrupt positioning (DVIT) instruction.
Pulse output
destination device
*1.
Caution:
If a user interrupt input command (M8460 to M8463) is specified in the interrupt input signal, the logic of the
user interrupt input command cannot be specified. This is because turning on the user interrupt input
command will turn on the interrupt input signal.
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
A device can only be specified if an FX
When using an FX
PLC below Ver. 2.20, if "8" is set and then the specified interrupt positioning
3UC
(DVIT) instruction turns ON, an operation error (error code: K6763) will occur, and the instruction will
not cause any operation.
Y003 is available only when two high-speed output special adapters are connected to the FX
After setting a number in the range of 9 to E for the interrupt input signal, if the corresponding interrupt
positioning (DVIT) instruction turns ON, an operation error (error code: K6763) will occur, and the
instruction will not cause any operation.
Interrupt input
signal
Y000
X003
Y001
M8461
Y002
Unused
*5
Unused
Y003
Y003 is available only when two high-speed output special adapters are connected to the FX
For details on the interrupt input signal designation method, refer to
"Interrupt signal logic
reverse" relay
Y000
Y001
Y002
*1
Y003
Y003 is available only when two high-speed output special adapters are connected to the FX
search engine
/FX
PLC Ver. 2.20 or later is used.
3U
3UC
M8000
Setting value
RUN monitor
3
8
F
F
For operation of DVIT instruction, refer to Chapter 9.
M8347
OFF: Positive logic (Turning the input ON will turn on the
M8357
interrupt input signal.)
M8367
ON: Negative logic (Turning the input OFF will turn on the
interrupt input signal.)
M8377
4 Before Programming
4.3 Various Special Relays for Operation Commands
FNC 12
HFF83
MOVP
Subsection 4.3.7.
Description
A
PLC.
3U
B
Apx.
D8336
M8336
PLC.
3U
PLC.
3U
B - 63

Advertisement