1.5.2

Assignment of Output Numbers

FX
1.
3S
Application
Pulse train signal
(Pulse output
destination)
Direction signal
(Rotational
direction signal)
CLEAR signal
*1.
*2.
B - 12
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
X000 to X005 for FX
PLC.
3S
Interrupt outputs are supported only in the FX
Y003 can be specified as the pulse output destination only if 2 high-speed output special adapters are
connected to the FX
PLC.
3U
Ver. 2.20 is assigned to the initial product of the FX
Y002 is not available in FX
/FX
/FX
/FX
/FX
3G
3GC
3U
3UC
Output
number
Y000
Connect a line to the output (Y000 - Y002) specified for the pulse output
Y001
designation (this output is specified by the positioning instruction).
*1
Y002
Connect a line to any output.
All output
Connect a line to the output specified for the rotation direction signal (this signal is
*2
points
specified by the positioning instruction).
Connect a line if it is necessary to use DSZR/ZRN instruction to output the CLEAR
signal.
The CLEAR signal output depends on the pulse output destination specified by
the DSZR/ZRN instruction. If the PLC version is later than the following number,
the CLEAR signal can be specified.
All output
*2
points
Y002 is not available in FX
Specify an output number for transistor output.
search engine
and FX
3U
3U
PLC (14-point and 24-point type) and FX
3G
Series main unit (transistor output)
Pulse output destination
Y000
Y001
*1
Y002
FX
PLC Ver. 2.20 or later and FX
3UC
If the CLEAR signal device specification function is used, the CLEAR signal
device specification register can specify an output for each pulse output
destination.
 For details on the CLEAR signal device specification method, refer to
The CLEAR signal device specification register depends on the pulse output
destination as shown in the following table:
Pulse output destination
Y000
Y001
*1
Y002
PLC (14-point and 24-point type) and FX
3G
1.5 Assignment of Input/Output Numbers
PLC.
3UC
PLC.
/FX
3S
3GC
Remarks
CLEAR signal
Y004
Y005
Y006
/FX
/FX
/FX
3S
3G
3GC
CLEAR signal device specification register
D8464
D8465
D8466
/FX
3S
3GC
1 Outline
PLC.
PLC:
3U
Subsection 4.3.4.