Special Adapter (Differential Line Driver Output - Mitsubishi Electric FX3S Series User Manual

Hide thumbs Also See for FX3S Series:
Table of Contents

Advertisement

FX
/FX
/FX
3S
3G
3GC
Common Items
1.2.3

Special Adapter (Differential Line Driver Output)

The special adapter can output pulse trains of up to 200 kHz using the positioning functionality incorporated in
the FX
Up to 2 high-speed output special adapters (FX
• The first FX
• The second FX
FX
-2HSY-ADP
3U
2nd
Cautions when connecting special adapters
• To use high-speed output special adapters only (not to use the other special adapters), it is not necessary
to connect the expansion board.
• To use the analog, communication, and CF card special adapters, be sure to connect the expansion board.
• To use high-speed output special adapters together with the analog, communication, and/or CF card
special adapters, connect the high-speed output special adapters to the expansion board (already
connected to the FX
CF card special adapter(s).
Communication special adapter
A - 6
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
PLC, and can simultaneously control up to 4 axes.
3U
-2HSY-ADP uses Y000 and Y004, and Y001 and Y005.
3U
-2HSY-ADP uses Y002 and Y006, and Y003 and Y007.
3U
FX
PLC
1st
3U
1-axis
Servo motor
(Servo amplifier)
Y000
+
Y004
PLC) first, and then connect the analog special adapters, communication, and/or
3U
Analog special adapter
CF card special adapter
search engine
1.2 Introduction of Products Needed for Positioning
-2HSY-ADP) can be connected to the FX
3U
2-axes
Servo motor
(Servo amplifier)
(Servo amplifier)
Y001
Y002
+
+
Y005
Y006
High-speed output
Expansion board
special adapter
RDA
RD
RDB
SDA
SD
SDB
SG
3U
3-axes
4-axes
Servo motor
Servo motor
(Servo amplifier)
Y003
+
Y007
FX
PLC
3U
1 Introduction
PLC.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3g seriesFx3gc seriesFx3u seriesFx3uc series

Table of Contents