Connection of the High-Speed Output Special Adapter

1. When the FX
the main unit should have enough input terminals. Before selecting the main unit, be sure to
check the number of input points required for the operation.
2. Specify the rotational direction signal of the positioning instruction depending on the
setting of each pulse output destination as shown in the following table:
3. To output the CLEAR signal using DSZR/ZRN instruction
The CLEAR signal output that is initially set for the DSZR/ZRN instruction is the same output as the direction
signal/reverse pulse train (rotation direction signal). Be sure to specify an output number of another transistor
output using the CLEAR signal
4. If the high-speed output special adapter is connected to the FX
output numbers will be assigned in the same way as the main unit.
If an output number assigned to a high-speed output special adapter is turned on by the sequence program,
the corresponding output of the main unit will also be turned on. Do not connect a line to both output
terminals. Connect a line to only one of the output terminals.
The outputs of the high-speed output special adapter and the main unit will be turned on as shown in the
following table:
FX
3U
of relay output type
FX
3U
of transistor output
type
FX
3U
of triac output type
High-speed output
special adapter
*1.
*2.
*3.
B - 14
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
-16MR/ES uses an instruction that requires the high-speed input operation,
3U
Pulse output destination
1st
2nd
device specification
 For details on the CLEAR signal device specification method, refer to
PLSY,PLSR,DSZR,
Unit
DVIT,TBL,ZRN,PLSV,
DRVI,DRVA instruction.
While instruction is
Series main unit
activated, relevant
output is ON. (LED is
also ON.)
Series main unit
*1
Operated
While instruction is
Series main unit
activated, relevant
output is ON. (LED is
also ON.)
Operated
The output frequency limit of the main unit transistor output is 100 kHz. When operating a load with a
pulse frequency exceeding 100 kHz, PLC failure may occur.
Furthermore, use of the PWM (FNC 58) is not recommended with the relay type main unit and the
high-speed adapters due to chattering of the relay contacts.
The PWM instruction dose not support the triac output due to response delay of outputs.
search engine
Rotation direction signal
Y000
Y001
Y002
Y003
function.
Output operation
Use of the PWM (FNC 58) instruction is not
compatible with a relay type main unit.
Operated
Use of the PWM (FNC 58) instruction is not
compatible with a triac type main unit.
Operated
The main unit should use the transistor output
*2
type.
1.5 Assignment of Input/Output Numbers
Y004
Y005
Y006