Built-in Positioning Functions
Application
Interrupt input
Forward
rotation limit
(LSF)
Reverse rota-
tion limit (LSR)
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Input number
The interrupt input depends on the pulse output destination specified by the DVIT
instruction
1.30 or higher, the interrupt input can be specified.
X000 to X007
Connect a line to any input.
If the line-connected input is turned on, the forward limit relay must be turned on.
The forward limit relay depends on the pulse output destination as shown in the
following table.
All input
points
Connect a line to any input.
If the line-connected input is turned on, the reverse limit relay must be turned on.
The reverse limit relay depends on the pulse output destination as shown in the
following table:
All input
points
search engine
*2
as shown in the following table. If the version number of the PLC is
Pulse output destination
Y000
Y001
Y002
*3
Y003
FX
PLC Ver. 1.30 or later
3UC
If the interrupt input specification function is used, register
D8336 (interrupt input specification register) can specify the
interrupt input number (X000 - X007) for each pulse output
destination.
 For details on the interrupt input specification method, refer to
*4
FX
/FX
PLC
Ver. 2.20 or later
3U
3UC
If the interrupt input specification function is used, register
D8336 (interrupt input specification register) can specify the
interrupt input number (X000 - X007) for each pulse output
destination, or the user interrupt input command can be
specified.
 For details on the user interrupt input command, refer to
The user interrupt input command depends on the pulse output destination as
shown in the following table.
Pulse output destination
Y000
Y001
Y002
*3
Y003
Pulse output destination
Y000
Y001
*5
Y002
*3
Y003
Pulse output destination
Y000
Y001
*5
Y002
*3
Y003
1.5 Assignment of Input/Output Numbers
Remarks
Interrupt input
X000
X001
X002
X003
Subsection 4.3.7.
Subsection 4.3.7.
User interrupt input command
M8460
M8461
M8462
M8463
Forward limit relay
M8343
M8353
M8363
M8373
Reverse limit relay
M8344
M8354
M8364
M8374
1 Outline
A
B
Apx.
B - 11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3g seriesFx3gc seriesFx3u seriesFx3uc series