Appendix 6.12 Cpuevt.csv (Event Setting - Cpu Event Setting) - Mitsubishi Electric MELSEC Q Series User Manual

Programmabale web server module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

APPENDICES

Appendix 6.12 CPUEVT.CSV (Event setting - CPU event setting)

Item
File name
File contents
File format
App - 54
(1) File format
CPUEVT.CSV
Event setting - CPU event setting (Refer to Section 6.5.3)
ITEM
CPUNO INTERVAL
CPUEVT1
1
CPUEVT2
3
CPUEVT5
15
CPUEVT60
64
1
9
10
PAUSE
EMAIL
NO
YES
NO
YES
1)
YES
YES
NO
NO
BODY
Error occurred on Line A. \nPerform recovery.
Error occurred on Line B. \nPerform recovery.
2)
Assembly line stopped.
14
APPTAG
APPLOGGING
15
3)
22
21
22
EMAIL6
EMAIL7
NO
NO
NO
NO
4)
NO
NO
29
30
EMAIL14
EMAIL15
NO
NO
NO
NO
5)
NO
NO
Label column : Cannot be set by the user.
Setting area : Set by the user.
Description
2
3
4
NSTOP
1
NO
2
NO
5
YES
10
NO
11
DISCONNECT
YES
NO
2)
YES
12
15
16
17
EMAIL1
EMAIL2
NO
YES
YES
NO
YES
NO
23
24
EMAIL8
EMAIL9
NO
NO
NO
NO
NO
NO
31
EMAIL16
NO
NO
NO
5
6
7
NRUN
WSTOP
WRUN
NO
NO
NO
NO
NO
NO
NO
YES
NO
NO
NO
NO
13
APPEND
NONE
TAG
LOGGING
18
19
EMAIL3
EMAIL4
YES
NO
YES
NO
YES
NO
25
26
27
EMAIL10
EMAIL11
EMAIL12
NO
NO
NO
NO
NO
NO
NO
NO
NO
MELSEC-Q
8
SERROR
YES
YES
1)
YES
YES
3)
20
EMAIL5
NO
NO
4)
NO
28
EMAIL13
NO
NO
5)
NO
App - 54

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71ws96

Table of Contents