Mitsubishi Electric MELSEC Q Series User Manual page 499

Programmabale web server module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

9 TROUBLE SHOOTING
Error
Error name
code
Device specification
0A0Ch
error
Device consistency
0A0Dh
error
0A0Eh
Same account error
No administrator
0A0Fh
authority error
Same logging file
0A10h
name error
Excessive number of
0A11h
device points for high
speed sampling tag
Duplicate high speed
sampling tag
0A12h
specification error
High speed sampling
0A13h
tag CPU specification
error
Duplicate high speed
0A14h
logging specification
error
0AA0h
System error
0B00h
Parameter error
Communication part
0B01h
error
No setting error
0B02h
9 - 44
Error definition
An incorrect device (that cannot
be handled) was specified in the
component setting.
Bits were specified for a word
device or any other than bits were
specified for a bit device.
The account of the same name
already exists.
Deletion of the last user account
with administrator authority was
attempted.
The logging file of the same name
already exists.
The total device points of the high
speed sampling tag exceeds 96
points.
The high speed sampling tag is
already set.
The component of other than the
access target CPU setting No. 1
exists in the high speed sampling
tag.
The high speed logging is already
set.
The parameter setting of the user
part is incorrect.
No communication part is provided
or a applet part is described
before a communication part.
Tag monitor was displayed with no
tag setting, or logging monitor was
displayed with no logging setting.
(From the previous page)
Corrective action
 Check the device in the
component setting. (Refer to
Section 6.3.3)
 Check the data type of the
component setting.
(Refer to Section 6.3.3)
 Specify another user name.
(Refer to Section 4.6.5)
 Enter at least one more user
account with administrator
authority before deletion.
(Refer to Section 4.6.5)
 Specify another logging file
name.
 Check the component setting of
the high speed sampling tag
(refer to Section 6.3.3), and
make setting so that the total
device points do not exceed 96
points.
 After deleting the already set high
speed sampling tag, set it again.
 Check the component setting.
(Refer to Section 6.3.3)
 After deleting the already set
high speed logging, set it again.
 System error ( 1)
 Check the parameter setting of
the user part.
 Describe only one
communication part in HTML
before applet parts.
 Perform tag setting.
(Refer to Section 6.3.3)
 Perform logging setting.
(Refer to Section 6.4.4)
(Continued on the next page)
MELSEC-Q
Error type
Display
Display
Display
Display
Display
Display
Display
Display
Display
Stop
Display
Display
Display
9 - 44

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71ws96

Table of Contents