Mitsubishi Electric MELSEC Q Series User Manual page 54

Programmabale web server module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

2 SYSTEM CONFIGURATION
Item
Protocol
Method of authentication
IP address
E-mail (When being set)
2 - 9
(6) RS-232 cable
When wiring, use applicable wires described below.
Connector
Length
RS-232
15m or less
connector
1 The recommenced cable is:
7/0.127
P HRV-SV...
"7/0.127 13P HRV-SV", the number of pairs of the cable is 13.)
The cable is manufactured by Oki Electric Cable Co., Ltd. (www.okidensen.co.jp/en)
(7) Internet service provider
The following table provides the specifications of the Internet service provider to
be connected to the Web server module.
PPP (Point to Point Protocol)
PAP or CHAP (Operable without authentication)
Global IP address must be assigned. ( 1)
SMTP server must be prepared. ( 2)
1 When using a UPnP-incompatible router type ADSL modem or broadband router, it is
necessary for the user to make a contract on a static IP address with an Internet
service provider and make the NAT setting of the router.
2 It must be able to access with "No authentication", "POP before SMTP" or "SMTP-
Auth".
Wire ( 1)
Diameter
Type
28 to
Stranded
24AWG
represents the number of pairs. (When the model name is
Specifications
MELSEC-Q
Material
Temperature rating
Copper
60°C or more
2 - 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71ws96

Table of Contents