6 FUNCTIONS

6.11 Diagnostics Function

6.11.1 Diagnostics function
6 - 129
This section explains the function to diagnose the hardware fault and setting of the
Web server module.
The following explains the method to diagnose the hardware fault and setting of the
Web server module.
(1)
Self-diagnostics test by switch setting of GX Developer (refer to Section 4.8)
A self-diagnostics test can be conducted by switch setting of GX Developer.
(a)
CH1 self-loopback test (refer to Section 4.8.1)
Conduct a self-loopback test to make a hardware check including the
communication function of the CH1 (10BASE-T/100BASE-TX interface).
(b)
CH2 self-loopback test (refer to Section 4.8.2)
Conduct a self-loopback test to make a hardware check including the
communication function of the CH2 (RS-232 interface).
(c)
Hardware test (refer to Section 4.8.3)
Conduct a test related to the ROM/RAM/switch setting of the Web server
module.
(2) Setting test by Web browser (refer to Section 6.11.2)
On the Setting test screen of the Administrative menu, an access target CPU test,
e-mail sending test, etc. can be performed from the Web server module.
(a)
Access target CPU test
Whether normal access can be made to the access target programmable
controller CPU set in the access target CPU setting is confirmed.
(b)
E-mail sending test
E-mail is sent to the destination e-mail address set in the e-mail setting to
confirm the e-mail send status.
(c)
File transfer test
A test file is transferred to the FTP server set in the FTP setting to confirm
the file transfer status.
(d)
PING test
The PING command is issued to the specified external device (mail server,
FTP server, etc.) to confirm the existence of the external device.
(3) PING test by IBM-PC/AT-compatible personal computer (refer to
Section 6.11.3)
The PING command can be issued from the external device (IBM-PC/AT-
compatible personal computer) to the Web server module to confirm the
existence of the Web server module.