9 TROUBLE SHOOTING
Error
Error name
code
0436h
Reference error
0437h
Duplicate label error
0438h
Component type error
CF card initialization
0480h
error
CF card drive data
0481h
retrieve error
0482h
CF card mount failure
0483h
0490h
0491h
System error
0492h
0493h
0494h
CF card format error
0495h
CF card check error
0496h
CF card response error
9 - 25
Error definition
The setting referred to by the item
value does not exist.
The same labels exist.
A string type component was
specified in the tag event setting.
The CF card cannot be initialized.
The drive data of the CF card
cannot be read.
Failed to mount the CF card
because a CF card error has been
detected.
Failed to format the CF card.
Failed to check the CF card.
A time-out occurred during waiting
for a response from the CF card
when access was made to the CF
card. (CF card failure)
(From the previous page)
Corrective action
 Check the item of the file
displayed in Status on the data
management screen, and
execute CSV import again.
(Refer to Section 6.10.4,
Appendix 6.)
 Check the label of the file
displayed in Status on the data
management screen, and
execute CSV import again.
(Refer to Section 6.10.4,
Appendix 6.)
 Check the contents of
TAGEVT.CSV and execute CSV
import again. (Refer to Section
6.10.4, Appendix 6.6)
 Check whether the CF card has
been set securely.
(Refer to Section 4.9)
 Replace the CF card.
 System error ( 1)
 Check whether the CF card is set
securely.
(Refer to Section 4.9)
 Check the CF card for a fault.
(Perform disk check and
formatting on the personal
computer.)
 Check whether the CF card is
faulty. (Execute Check disk or
format on the personal computer,
etc.)
 Replace the CF card.
(Continued on the next page)
MELSEC-Q
Error type
Display
Display
Display
Continue
Stop
Display
Display
Continue
9 - 25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71ws96

Table of Contents