Mitsubishi Electric MELSEC Q Series User Manual page 96

Programmabale web server module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

3 SPECIFICATIONS
3 - 40
(5) Number of connection tries by automatic connection (Address: 34)
This area stores the cumulative number of attempted automatic connection from
the Web server module to the network.
Refer to X4 of Section 3.6.2 (1) for the trigger of connection to the network.
(6) Number of reconnection tries (Address: 35)
(a)
This area stores the number of reconnection to the network.
(b)
When connection is cut off unintentionally due to cable disconnection in the
network connection status or line disruption by the Internet service provider,
the Web server module makes reconnection to the network automatically
only once.
(c)
When the number of retries and multiple access points have been set in the
dial-up setting, reconnection is performed for the number of retry times
multiplied by the number of multiple access points.
(7) Number of times of connection retry occurrence (Address: 36)
This area stores the number of connection tries (including initial time) during
network connection the number 05 multiplied by the number of access points.
(8) Number of disconnection (Address: 37)
This area stores the cumulative number of disconnection from the network.
Refer to X4 of Section 3.6.2 (1) for the trigger of disconnection from the network.
(9) Number of disconnection by request signal (Y7) (Address: 38)
This area stores the cumulative number of disconnection from the network by
Network disconnection request (Y7).
(10) Number of automatic disconnection (Address: 39)
This area stores the cumulative number of automatic disconnection from the
network.
Refer to X4 of Section 3.6.2 (1) for the trigger of disconnection from the network.
(11) Number of line lost times (Address: 40)
This area stores the cumulative number of unintentional disconnection from the
network due to cable disconnection in a network connection status or line
disruption from the Internet service provider.
(12) Total connection time (Address: 41 to 42)
This area stores the total time of connection to the network from the start-up time
of the Web server module. (Unit: Minute)
(13) LAN connection time (Address: 43 to 44), Modem connection time
(Address: 45 to 46), ADSL connection time (Address: 49 to 50)
This area stores the time of the network connection for each connection method.
(Unit: Minute)
MELSEC-Q
3 - 40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71ws96

Table of Contents