Wave output function procedure
The following shows how to use the wave output function.
1.
Creating wave data
Page 52 Creating wave data
2.
Setting parameters of the wave output function
Page 56 Setting parameters of the wave output function
3.
Writing wave output data to a file register (ZR) or CSV file
Page 57 Writing data to a file register (ZR) or CSV file
4.
Setting parameters of D/A converter module
Page 58 D/A conversion enable/disable setting
5.
Registering wave output data
Page 58 Registering wave output data
6.
Starting/stopping/pausing wave output
Page 60 Starting/stopping/pausing wave output
Wave output data can be created easily by using "Create Wave Output Data" of the engineering tool. This data can be saved
in the CSV file or file register (ZR) of the CPU module.
For details on the function block (FB) for registering wave output data and executing wave output, refer to the following.
MELSEC iQ-R Analog-Digital Converter Module/Digital-Analog Converter Module Function Block Reference
■Feature of the file register (ZR) and CSV file to which wave data is saved
• When saving data to the file register (ZR), wave output data is held in the CPU module even after powering off or resetting
the CPU module.
• When saving data to the CSV file, wave output data can easily be reused for the D/A converter module of other
programmable controller systems by simply copying the CSV file.
Parameter settings for the wave output function
Set the parameters of the wave output function to the following buffer memory areas to use the wave output function.
Setting item
Output setting during wave output stop
Output value during wave output stop
Wave pattern start address setting
Wave pattern data points setting
Wave pattern output repetition setting
Constant for wave output conversion cycle
Wave data registry area
For details on the parameter settings for the wave output function, refer to the following.
Page 56 Setting parameters of the wave output function
1 FUNCTIONS
46
1.14 Wave Output Function
Details of buffer memory areas
Page 174 CH1 Output setting during wave output stop
Page 175 CH1 Output value during wave output stop
Page 176 CH1 Wave pattern start address setting
Page 177 CH1 Wave pattern data points setting
Page 177 CH1 Wave pattern output repetition setting
Page 178 CH1 Constant for wave output conversion cycle
Page 187 Wave data registry area