CH1 Wave pattern output count monitor
Wave
The output count of the wave pattern is stored in this area.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Wave pattern output count monitor
■Count of the wave pattern output
The stored value increases by one every time one cycle of a wave pattern is output.
■Count range of the wave pattern output
The count range is from 0 to 32767.
When wave pattern output count is set to Unlimited repeat output, the count returns to 0 and starts again from 1 after the
32767th count. (3276632767012)
■Resetting the stored value
In the following cases, the stored value is reset.
• When 'Operating condition setting request' (Y9) is turned on and off
• When the wave output status transitions from its stop status to another
CH1 Wave output current address monitor
Wave
This area stores the buffer memory address of the currently output wave data in 32-bit signed binary for each channel.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Wave output current address monitor
■Update of the stored value
The stored value is updated when the wave output status is During wave output or During wave output step action.
■Resetting the stored value
When 'Operating condition setting request' (Y9) is turned on and off, the stored value is reset.
APPX
164
Appendix 3 Buffer Memory Areas
CH1
CH2
434
634
CH1
CH2
436, 437
636, 637
CH3
CH4
834
1034
CH3
CH4
836, 837
1036, 1037