Mitsubishi Electric MELSEC iQ-R Series User Manual page 146

High speed digital-analog converter module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

User range write request
Normal
■Device number
The following shows the device number of this output signal.
Signal name
User range write request
■In the offset/gain setting mode
Turn on and off User range write request to register values adjusted with the offset/gain setting in the D/A converter module.
The data is written to the flash memory when this signal is turned on.
For the timing of turning on and off the signal, refer to the following.
Page 139 Offset/gain setting mode status flag
■In the normal output mode
Turn on and off 'User range write request' (YA) to restore the user range.
For the timing of turning on and off the signal, refer to the following.
Page 139 Offset/gain setting mode status flag
Channel change request
Normal
Turn on and off 'Channel change request' (YB) to change a channel to perform the offset/gain setting.
For the timing of turning on and off the signal, refer to the following.
Page 140 Channel change completed flag
■Device number
The following shows the device number of this output signal.
Signal name
Channel change request
Set value change request
Normal
Turn on and off 'Set value change request' (YC) to change the analog output value to adjust the offset/gain setting.
The analog output value increases or decreases depending on the value set for 'Offset/gain adjustment value specification'
(Un\G4130).
For the timing of turning on and off the signal, refer to the following.
Page 140 Set value change completed flag
■Device number
The following shows the device number of this output signal.
Signal name
Set value change request
APPX
144
Appendix 2 I/O Signals
CH1
CH2
YA
CH1
CH2
YB
CH1
CH2
YC
CH3
CH4
CH3
CH4
CH3
CH4