Wave Output Function - Mitsubishi Electric MELSEC iQ-R Series User Manual

High speed digital-analog converter module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

1.14

Wave Output Function

Wave
This function registers the prepared wave data (digital value) on the D/A converter module and continuously outputs the data
(analog value) in the set conversion cycle. A faster and smoother control than a program is achieved by the automatic output
of the control wave data registered in the D/A converter module for the analog (torque) control such as pressing machines and
injection molding units. The control can be executed only by registering the wave data to the D/A converter module.
Therefore, the program-less control is available for the repeat control such as the line control, and man-hours for
programming can be reduced.
In this section, the following items set in the wave output function are called wave output data.
• Wave data (Page 47 Wave data)
• Parameters of the wave output function (Page 56 Setting parameters of the wave output function)
(1)
(2)
(1) Wave data can be created from "Create Wave Output Data" of the engineering tool with easy mouse operation.
(2) Wave data is stored to a CSV file or file register. CSV files are saved in an SD memory card.
(3) Wave data is registered in the wave data registry area of D/A converter module with the function block (FB) for registering wave data.
(4) The data is successively converted in the set conversion cycle and output in analog.
Wave data
D/A
converter
module
(3)
Wave data registry area
Analog
output
(4)
Object to be
controlled
1.14 Wave Output Function
1
1 FUNCTIONS
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60dah4

Table of Contents