K-## Keypad Set-Up - GE AF-650 GP Programming Manual

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Lists

4.1.2 K-## Keypad Set-up

Par. No.
Parameter description
#
K-0#
K-01
Language
K-02
Motor Speed Unit
4
4
K-03
Regional Settings
K-04
Operating State at Power-up
K-1#
K-10
Active Set-up
K-11
Edit Set-up
K-12
This Set-up Linked to
K-13
Readout: Linked Set-ups
K-14
Readout: Edit Set-ups / Channel
K-15
Readout: actual setup
K-2#
K-20
Display Line 1.1 Small
K-21
Display Line 1.2 Small
K-22
Display Line 1.3 Small
K-23
Display Line 2 Large
K-24
Display Line 3 Large
K-25
Quick Start
K-3#
K-30
Unit for Custom Readout
K-31
Min Value of Custom Readout
K-32
Max Value of Custom Readout
K-37
Display Text 1
K-38
Display Text 2
K-39
Display Text 3
K-4#
K-40
[Hand] Button on Keypad
K-41
[Off] Button on Keypad
K-42
[Auto] Button on Keypad
K-43
[Reset] Button on Keypad
K-5#
K-50
Keypad Copy
K-51
Set-up Copy
K-6#
K-60
Main Menu Password
K-61
Access to Main Menu w/o Password
K-65
Quick Menu Password
K-66
Access to Quick Menu w/o Password
K-67
Bus Password Access
4.1.3 F-## Fundamental Parameters
Par. No.
Parameter description
#
F-0#
F-01
Frequency Setting 1
F-02
Operation Method
142
AF-650 GP Programming Guide
Default value
[0] English
[0] RPM
[1] US
[1] Forced stop, ref=old
[1] Set-up 1
[1] Set-up 1
[0] Not linked
0 N/A
0 N/A
0 N/A
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] None
0 CustomReadoutUnit
100 CustomReadoutUnit
0 N/A
0 N/A
0 N/A
[1] Enabled
[1] Enabled
[1] Enabled
[1] Enabled
[0] No copy
[0] No copy
100 N/A
[0] Full access
200 N/A
[0] Full access
0 N/A
Default value
ExpressionLimit
[0] Linked to Hand / Auto
DET-618C
4-set-up
Change
Conver-
during
sion
operation
index
1 set-up
TRUE
2 set-ups
FALSE
2 set-ups
FALSE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
-2
All set-ups
TRUE
-2
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
4-set-up
Change
Conver-
during
sion
operation
index
All set-ups
TRUE
All set-ups
TRUE
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
0
Int32
0
Uint8
-
Uint16
-
Uint16
-
Uint16
-
Uint16
-
Uint16
0
Uint16
-
Uint8
Int32
Int32
0
VisStr[25]
0
VisStr[25]
0
VisStr[25]
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Int16
-
Uint8
0
Int16
-
Uint8
0
Uint16
Type
-
Uint8
-
Uint8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents