GE AF-650 GP Programming Manual page 101

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Descriptions
PB-71 Profibus Save Data Values
Option:
3
3
[0]
Off
*
[1]
Store edit
setup
[2]
Store all
setups
PB-72 ProfibusDriveReset
Option:
[0]
No action
*
[1]
Power-on reset
[2]
Power-on reset
prep
[3]
Comm option
reset
PB-80 Defined Parameters (1)
Array [116]
No keypad access
Read only
Range:
0
[0 - 9999] This parameter displays a list of all the defined
*
PB-81 Defined Parameters (2)
Array [116]
No keypad access
Read only
Range:
0
[0 - 9999] This parameter displays a list of all the defined
*
100
AF-650 GP Programming Guide
Function:
Parameter values changed via Profibus are not
automatically stored in non-volatile memory.
Use this parameter to activate a function that
stores parameter values in the EEPROM non-
volatile memory, so changed parameter values
will be retained at power-down.
Deactivates the non-volatile storage function.
Stores all parameter values for all set-ups in the
non-volatile memory. The selection returns to
[0] Off when all parameter values have been
stored.
Stores all parameter values for all set-ups in the
non-volatile memory. The selection returns to
[0] Off when all parameter values have been
stored.
Function:
Resets frequency converter upon power-
up, as for power-cycle.
Resets the Profibus option only, useful
after changing certain settings in
parameter group PB-##, for example,
PB-18 Node Address.
When reset, the frequency converter
disappears from the Network, which may
cause a communication error from the
master.
Function:
frequency converter parameters available for
Profibus.
Function:
frequency converter parameters available for
Profibus.
PB-82 Defined Parameters (3)
Array [116]
No keypad access
Read only
Range:
Function:
0
[0 - 9999] This parameter displays a list of all the defined
*
frequency converter parameters available for
Profibus.
PB-83 Defined Parameters (4)
Array [116]
No keypad access
Read only
Range:
Function:
0
[0 - 9999] This parameter displays a list of all the defined
*
frequency converter parameters available for
Profibus.
PB-84 Defined Parameters (5)
Range:
Function:
0
[0 - 9999] This parameter displays a list of all the defined
*
frequency converter parameters available for
Profibus.
PB-90 Changed Parameters (1)
Array [116]
No keypad access
Read only
Range:
Function:
0
[0 - 9999] This parameter displays a list of all the frequency
*
converter parameters deviating from default
setting.
PB-91 Changed Parameters (2)
Array [116]
No keypad access
Read only
Range:
Function:
0
[0 - 9999] This parameter displays a list of all the frequency
*
converter parameters deviating from default
setting.
PB-92 Changed Parameters (3)
Array [116]
No keypad access
Read only
Range:
Function:
0
[0 - 9999] This parameter displays a list of all the frequency
*
converter parameters deviating from default
setting.