Parameter Descriptions
ID-22 Historic Log: Time
Array [50]
Range:
Function:
0 ms
[0 - 2147483647
View the time at which the logged
*
ms]
event occurred. Time is measured in
ms since frequency converter start.
The max. value corresponds to
approx. 24 days which means that the
count will restart at zero after this
time period.
3.17.4 ID-3# Alarm Log
View up to 10 alarm logs. The data is stored in array
parameters, where [0] is the most recent and [9] is the
oldest data. Error codes, values, and time stamp can be
viewed for all logged data.
ID-30 Fault Log: Error Code
Array [10]
Range:
Function:
0
[0 - 255] View the error code and look up its meaning in
*
5 Troubleshooting.
ID-31 Alarm Log: Value
Array [10]
Range:
Function:
0
[-32767 - 32767] View an extra description of the error. This
*
parameter is mostly used in combination
with alarm 38 'internal fault'.
ID-32 Alarm Log: Time
Array [10]
Range:
Function:
0 s
[0 - 2147483647 s] View the time when the logged event
*
occurred. Time is measured in seconds
from frequency converter start-up.
3.17.5 ID-4# Drive Identification
Parameters to view the information about the hardware
and software configuration of the drive.
ID-40 Drive Type
Range:
Function:
0
[0 - 0]
View the frequency converter type.
*
ID-41 Power Section
Range:
Function:
0
[0 - 0]
View the power section.
*
AF-650 GP Programming Guide
ID-42 Voltage
Range:
0
*
ID-43 Software Version
Range:
0
*
ID-46 GE Product No.
Range:
0
*
ID-47 GE Power Card Model No
Range:
0
[0 - 0]
*
ID-48 Keypad ID Number
Range:
0
[0 - 0]
*
ID-49 SW ID Control Card
Range:
0
[0 - 0]
*
ID-50 SW ID Power Card
Range:
0
[0 - 0]
*
ID-51 Drive Serial Number
Range:
0
[0 - 0]
*
ID-53 Power Card Serial Number
Range:
0
[0 - 0]
*
3.17.6 ID-6# Option Ident
Parameters to view the information about the hardware
and software configuration of the field installed I/O and
network option modules.
ID-60 Option Mounted
Array [8]
Range:
0
[0 - 0]
*
ID-61 Option SW Version
Array [8]
Range:
0
[0 - 0]
*
DET-618C
Function:
[0 - 0]
View the voltage.
Function:
[0 - 0]
View the SW version
Function:
[0 - 0]
View the 8-digit number.
Function:
View the power card model number.
Function:
View the keypad ID number.
Function:
View the control card software version number.
Function:
View the power card software version number.
Function:
View the frequency converter serial number.
Function:
View the power card serial number.
Function:
View the installed option type.
Function:
View the installed option software version.