Alarm; Warning Word; Table; Function - GE AF-650 GP Programming Manual

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Descriptions
ID-12 Trigger Event
Select the trigger event. When the trigger event occurs, a
window is applied to freeze the log. The log will then retain a
specified percentage of samples before the occurrence of the
trigger event (ID-14 Samples Before Trigger).
3
3
Choices are described under E-## Digital Output.
Option:
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[33]
[34]
[35]
[36]
[37]
[38]
[50]
[51]
[60]
[61]
ID-13 Trending Mode
Option:
[0]
Trend always
*
[1]
Trend once on
trigger
ID-14 Samples Before Trigger
Range:
50
[0 - 100] Enter the percentage of all samples prior to a
*
110
AF-650 GP Programming Guide
Below feedb. low
Above feedb. high
Thermal warning
Line voltage out of range
Reversing
Warning
Alarm (trip)
Alarm (trip lock)
Comparator 0
Comparator 1
Comparator 2
Comparator 3
Logic rule 0
Logic rule 1
Logic rule 2
Logic rule 3
Digital input DI18
Digital input DI19
Digital input DI27
Digital input DI29
Digital input DI32
Digital input DI33
Comparator 4
Comparator 5
Logic rule 4
Logic rule 5

Function:

Select [0] Log always for continuous
logging.
Select [1] Log once on trigger to
conditionally start and stop logging using
ID-12 Trigger Event and ID-14 Samples
Before Trigger.
Function:
trigger event which are to be retained in the log.
See also ID-12 Trigger Event and ID-13 Trending
Mode.
3.17.3 ID-2# Historic Log
View up to 50 data items logged up to the last reported
trip. The data is stored in array parameters, where [0] is the
most recent data and [49] is the oldest data.
ID-20 Historic Log: Event
Function:
Array [50]
Range:
0
[0 - 255]
*
ID-21 Historic Log: Value
Array [50]
Range:
0
[0 -
*
2147483647]
DET-618C
Function:
View the event type of the logged events.
Function:
View the value of the logged event.
Interpret the event values according to this

table:

Digtal input
Decimal value. See
DR-60 Digital Input for
description after
converting to binary
value.
Digital output
Decimal value. See
DR-66 Digital Output [bin]
for description after
converting to binary
value.
Warning word Decimal value. See
DR-92 Warning Word for
description.
Alarm word
Decimal value. See
DR-90 Alarm Word for
description.
Status word
Decimal value. See
DR-03 Status Word for
description after
converting to binary
value.
Control word
Decimal value. See
DR-00 Control Word for
description.
Extended
Decimal value. See
status word
DR-94 Ext. Status Word for
description.
Table 3.29

Hide quick links:

Advertisement

Table of Contents
loading