Parameter Descriptions
O-41 Parameters for Signals
Option:
[1235] Drive Thermal
[1238] Logic Controller State
[1239] Control Card Temp.
3
3
[1248] Speed Ref. After Ramp [RPM]
[1250] External Reference
[1251] Pulse Reference
[1252] Feedback[Unit]
[1253] Digi Pot Reference
[1257] Feedback [RPM]
[1260] Digital Input
[1261] Terminal 53 Switch Setting
[1262] Analog Input 53
[1263] Terminal 54 Switch Setting
[1264] Analog Input 54
[1265] Analog Output 42 [mA]
[1266] Digital Output [bin]
[1267] Freq. Input #29 [Hz]
[1268] Freq. Input #33 [Hz]
[1269] Pulse Output #27 [Hz]
[1270] Pulse Output #29 [Hz]
[1271] Relay Output [bin]
[1272] Counter A
[1273] Counter B
[1274] Prec. Stop Counter
[1275] Analog In X30/11
[1276] Analog In X30/12
[1277] Analog Out X30/8 [mA]
[1280] Fieldbus CTW 1
[1282] Fieldbus REF 1
[1284] Comm. Option STW
[1285] Drive Port CTW 1
[1287] Bus Readout Alarm/Warning
[1290] Alarm Word
[1291] Alarm Word 2
[1292] Warning Word
[1293] Warning Word 2
[1294] Ext. Status Word
[1500] Operating hours
[1501] Running Hours
[1502] kWh Counter
[1600] Control Word
O-42 PCD Write Configuration
Range:
[0]
None
*
[7]
Accel Time 1
[8]
Decel Time 1
[15]
Motor Speed High Limit [Hz]
[16]
Motor Speed Low Limit [Hz]
[17]
Motor Speed High Limit [RPM]
[18]
Motor Speed Low Limit [RPM]
[40]
Torque Limiter (Driving)
90
AF-650 GP Programming Guide
O-42 PCD Write Configuration
Function:
Range:
[41]
[52]
[53]
[62]
[110]
[111]
[190]
[193]
[195]
[197]
[222]
[223]
[653]
[663]
[748]
[890]
[891]
[1280]
[1282]
O-43 PCD Read Configuration
Range:
[0]
[515]
[1200]
[1201]
[1202]
[1203]
[1205]
[1209]
[1210]
[1211]
[1212]
[1213]
[1214]
[1215]
[1216]
[1217]
[1218]
[1219]
[1220]
[1221]
[1222]
Function:
[1225]
[1230]
[1232]
[1233]
[1234]
[1235]
[1238]
[1239]
[1248]
DET-618C
Torque Limiter (Braking)
Minimum Reference
Maximum Reference
Catch up/slow Down Value
Accel Time 2
Decel Time 2
Digital & Relay Bus Control
Pulse Out #27 Bus Control
Pulse Out #29 Bus Control
Pulse Out #X30/6 Bus Control
Jog Accel/Decel Time
Quick Stop Decel Time
Terminal 42 Output Bus Control
Terminal X30/8 Bus Control
PCD Feed Forward
Bus Jog 1 Speed
Bus Jog 2 Speed
Fieldbus CTW 1
Fieldbus REF 1
None
*
Readout: actual setup
Control Word
Reference [Unit]
Reference %
Status Word
Main Actual Value [%]
Custom Readout
Power [kW]
Power [hp]
Motor Voltage
Frequency
Motor current
Frequency [%]
Torque [Nm]
Speed [RPM]
Motor Thermal
KTY sensor temperature
Motor Angle
Torque [%] High Res.
Torque [%]
Torque [Nm] High
DC Link Voltage
Brake Energy /s
Brake Energy /2 min
Heatsink Temp.
Drive Thermal
Logic Controller State
Control Card Temp.
Speed Ref. After Ramp [RPM]
Function:
Function: