GE AF-650 GP Programming Manual page 32

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Descriptions
K-50 Keypad Copy
Option:
Function:
[0]
No copy
*
[1]
All to Keypad Copies all parameters in all set-ups from the
frequency converter memory to the keypad
memory.
[2]
All from
Copies all parameters in all set-ups from the
Keypad
keypad memory to the frequency converter
memory.
[3]
Size indep.
Copy only the parameters that are
From Keypad
independent of the motor size. The latter
selection can be used to program several
frequency converters with the same function
without disturbing motor data.
K-51 Set-up Copy
Option:
Function:
[0]
No copy
No function
*
[1]
Copy to set-
Copies all parameters in the present
up 1
Programming Set-up (defined in K-11 Edit
Set-up) to Set-up 1.
[2]
Copy to set-
Copies all parameters in the present
up 2
Programming Set-up (defined in K-11 Edit
Set-up) to Set-up 2.
[3]
Copy to set-
Copies all parameters in the present
up 3
Programming Set-up (defined in K-11 Edit
Set-up) to Set-up 3.
[4]
Copy to set-
Copies all parameters in the present
up 4
Programming Set-up (defined in K-11 Edit
Set-up) to Set-up 4.
[9]
Copy to all
Copies the parameters in the present set-up
over to each of the set-ups 1 to 4.
3.2.7 K-6# Password Protection
Parameters for setting the Password Protection for the
drive parameters.
K-60 Main Menu Password
Range:
Function:
100
[-9999 -
Define the password for access to the Main
*
9999]
Menu via the [Main Menu] key. If K-61 Access
to Main Menu w/o Password is set to [0] Full
access, this parameter will be ignored.
K-61 Access to Main Menu w/o Password
Option:
Function:
[0]
Full access
Disables password defined in K-60 Main
*
Menu Password.
[1]
Keypad: Read only Prevent unauthorized editing of Main
Menu parameters.
AF-650 GP Programming Guide
K-61 Access to Main Menu w/o Password
Option:
[2]
Keypad: No access Prevent unauthorized viewing and
[3]
Bus: Read only
[4]
Bus: No access
[5]
All: Read only
[6]
All: No access
If [0] Full access is selected then K-60 Main Menu Password,
K-65 Quick Menu Password and K-66 Access to Quick Menu
w/o Password will be ignored.
K-65 Quick Menu Password
Range:
200
[-9999 -
*
9999]
K-66 Access to Quick Menu w/o Password
Option:
[0]
Full access
*
[1]
Keypad: Read
only
[2]
Keypad: No
access
[3]
Bus: Read only
[4]
Bus: No access
[5]
All: Read only
[6]
All: No access
If K-61 Access to Main Menu w/o Password is set to [0] Full
access then this parameter will be ignored.
K-67 Bus Password Access
Range:
0
[0 - 9999] Writing to this parameter enables users to unlock
*
DET-618C
Function:
editing of Main Menu parameters.
Function:
Define the password for access to the Quick
Menu via the [Quick Menu] key. If
K-66 Access to Quick Menu w/o Password is
set to [0] Full access, this parameter will be
ignored.
Function:
Disables the password defined in
K-65 Quick Menu Password.
Prevents unauthorised editing of Quick
Menu parameters.
Prevents unauthorised viewing and
editing of Quick Menu parameters.
Read only functions for Quick Menu
parameters on Fieldbus and/ or Drive
standard bus.
No access to Quick Menu parameters is
allowed via Fieldbus and/ or Drive
standard bus.
read only function for Quick Menu
parameters on keypad, Fieldbus or Drive
standard bus.
No access from keypad, Fieldbus or Drive
standard bus is allowed.
Function:
the frequency converter from network/DCT-10.
3
3
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents