GE AF-650 GP Programming Manual page 31

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Descriptions
K-38 Display Text 2
Range:
0
[0 - 0] Enter a text which can be viewed in the graphical
*
display by selecting [38] Display Text 2 in
K-20 Display Line 1.1 Small, K-21 Display Line 1.2
3
3
Small, K-22 Display Line 1.3 Small, K-23 Display Line 2
Large or K-24 Display Line 3 Large.
K-39 Display Text 3
Range:
0
[0 - 0] Enter a text which can be viewed in the graphical
*
display by selecting [39] Display Text 3in K-20 Display
Line 1.1 Small, K-21 Display Line 1.2 Small,
K-22 Display Line 1.3 Small, K-23 Display Line 2 Large
or K-24 Display Line 3 Large.
3.2.5 K-4# Keypad Buttons
Parameters for configuring the graphical keypad Hand, Off,
Auto, & Reset keys.
K-40 [Hand] Button on Keypad
Option:
[0]
Disabled
[1]
Enabled
*
[2]
Password Protection Avoid unauthorized start in Hand
[3]
Enabled without
OFF
[4]
Password without
OFF
[5]
Enabled with OFF
[6]
Password with OFF
K-41 [Off] Button on Keypad
Option:
[0]
Disabled
[1]
Enabled
*
[2]
Password Protection
[3]
Hand Off/On
[4]
Hand Off/On w. Passw.
[7]
Enabled without OFF
30
Function:
Function:
Function:
Key disabled avoids accidental usage
of the key.
[Hand ] key enabled
mode. If K-40 [Hand] Button on
Keypad is included in the Quick Start
Menu, then define the password in
K-65 Quick Menu Password. Otherwise
define the password in K-60 Main
Menu Password.
Function:
Avoids accidental stop of the
frequency converter.
[Off] Key enabled
Avoids unauthorised stop. If
K-41 [Off] Button on Keypad is
included in the Quick Menu, then
define the password in K-65 Quick
Menu Password.
AF-650 GP Programming Guide
K-41 [Off] Button on Keypad
Option:
[8]
Password without OFF
[9]
Enabled, ref = 0
K-42 [Auto] Button on Keypad
Option:
[0]
Disabled
[1]
Enabled
*
[2]
Password Protection
[3]
Hand Off/On
[4]
Hand Off/On w. Passw.
[7]
Enabled without OFF
[8]
Password without OFF
[9]
Enabled, ref = 0
K-43 [Reset] Button on Keypad
Option:
[0]
Disabled
[1]
Enabled
*
[2]
Password
Protection
[3]
Hand Off/On
[4]
Hand Off/On w.
Passw.
[7]
Enabled without
OFF
[8]
Password without
OFF
[9]
Enabled, ref = 0
3.2.6 K-5# Copy/Save
Copy parameter settings between set-ups and to/from the
keypad.
K-50 Keypad Copy
Option:
DET-618C
Function:
Function:
Avoid accidental start of the
frequency converter in Auto mode.
[Auto] Key enabled
Avoids unauthorised start in Auto
mode. If K-42 [Auto] Button on
Keypad is included in the Quick
Menu, then define the password in
K-65 Quick Menu Password.
Function:
No effect when [Reset] is pressed.
Avoids accidental alarm reset.
[Reset] Key enabled
Avoids unauthorised resetting. If
K-43 [Reset] Button on Keypad is
included in the Quick Menu, then
define the password in K-65 Quick
Menu Password.
Resets the frequency converter
without setting it in Off mode.
Resets the frequency converter
without setting it in Off mode. A
password is required when pressing
[Reset] (see [2]).
Function:
NOTE
This parameter cannot be adjusted
while the motor is running.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents