Parameter Lists

4.1.4 E-## Digital In/Outs

Par. No.
Parameter description
#
E-0#
E-00
Digital I/O Mode
E-01
Terminal 18 Digital Input
4
4
E-02
Terminal 19 Digital Input
E-03
Terminal 27 Digital Input
E-04
Terminal 29 Digital Input
E-05
Terminal 32 Digital Input
E-06
Terminal 33 Digital Input
E-07
Terminal 37 Safe Stop
E-1#
E-10
Accel Time 2
E-11
Decel Time 2
E-12
Accel Time 3
E-13
Decel Time 3
E-14
Accel Time 4
E-15
Decel Time 4
E-2#
E-20
Terminal 27 Digital Output
E-21
Terminal 29 Digital Output
E-24
Function Relay
E-26
On Delay, Relay
E-27
Off Delay, Relay
E-5#
E-51
Terminal 27 Mode
E-52
Terminal 29 Mode
E-53
Terminal X30/2 Digital Input
E-54
Terminal X30/3 Digital Input
E-55
Terminal X30/4 Digital Input
E-56
Term X30/6 Digi Out (OPCGPIO)
E-57
Term X30/7 Digi Out (OPCGPIO)
E-6#
E-60
Term. 29 Low Frequency
E-61
Term. 29 High Frequency
E-62
Term. 29 Low Ref./Feedb. Value
E-63
Term. 29 High Ref./Feedb. Value
E-64
Pulse Filter Time Constant #29
E-65
Term. 33 Low Frequency
E-66
Term. 33 High Frequency
E-67
Term. 33 Low Ref./Feedb. Value
E-68
Term. 33 High Ref./Feedb. Value
E-69
Pulse Filter Time Constant #33
E-7#
E-70
Terminal 27 Pulse Output Variable
E-72
Pulse Output Max Freq #27
E-73
Terminal 29 Pulse Output Variable
E-75
Pulse Output Max Freq #29
E-76
Terminal X30/6 Pulse Output Variable
144
AF-650 GP Programming Guide
Default value
[0] PNP
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[1] Safe Stop Alarm
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] No operation
[0] No operation
ExpressionLimit
0.01 s
0.01 s
[0] Input
[0] Input
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] No operation
[0] No operation
100 Hz
100 Hz
0 ReferenceFeedbackUnit
ExpressionLimit
100 ms
100 Hz
100 Hz
0 ReferenceFeedbackUnit
ExpressionLimit
100 ms
[0] No operation
5000 Hz
[0] No operation
5000 Hz
[0] No operation
DET-618C
4-set-up
Change
Conver-
during
sion
operation
index
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
FALSE
-3
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
FALSE
-3
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
Uint32
Uint32
Uint32
Uint32
Uint32
Uint32
-
Uint8
-
Uint8
-
Uint8
Uint16
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint32
0
Uint32
Int32
Int32
Uint16
0
Uint32
0
Uint32
Int32
Int32
Uint16
-
Uint8
0
Uint32
-
Uint8
0
Uint32
-
Uint8