GE AF-650 GP Programming Manual page 49

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Descriptions
[72]
Logic Rule 2
[73]
Logic Rule 3
3
3
[74]
Logic Rule 4
[75]
Logic Rule 5
[80]
Logic Controller
Digital Output
A
[81]
Logic Controller
Digital Output B
[82]
Logic Controller
Digital Output
C
[83]
Logic Controller
Digital Output
D
[84]
Logic Controller
Digital Output E
[85]
Logic Controller
Digital Output F
[120] Local reference
active
[121] Remote
reference active
48
AF-650 GP Programming Guide
See parameter group LC-4#. If Logic Rule
2 is evaluated as TRUE, the output will
go high. Otherwise, it will be low.
See parameter group LC-4#. If Logic Rule
3 is evaluated as TRUE, the output will
go high. Otherwise, it will be low.
See parameter group LC-4#. If Logic Rule
4 is evaluated as TRUE, the output will
go high. Otherwise, it will be low.
See parameter group LC-4#. If Logic Rule
5 is evaluated as TRUE, the output will
go high. Otherwise, it will be low.
See LC-52 Logic Controller Action. The
output will go high whenever the Logic
Controller Action [38] Set dig. out. A high
is executed. The output will go low
whenever the Logic Controller Action
[32] Set dig. out. A low is executed.
See LC-52 Logic Controller Action. The
input will go high whenever the Logic
Controller Action [39] Set dig. out. A high
is executed. The input will go low
whenever the Logic Controller Action
[33] Set dig. out. A low is executed.
See LC-52 Logic Controller Action. The
input will go high whenever the Logic
Controller Action [40] Set dig. out. A high
is executed. The input will go low
whenever the Logic Controller Action
[34] Set dig. out. A low is executed.
See LC-52 Logic Controller Action. The
input will go high whenever the Logic
Controller Action [41] Set dig. out. A high
is executed. The input will go low
whenever the Logic Controller Action
[35] Set dig. out. A low is executed.
See LC-52 Logic Controller Action. The
input will go high whenever the Logic
Controller Action [42] Set dig. out. A high
is executed. The input will go low
whenever the Logic Controller Action
[36] Set dig. out. A low is executed.
See LC-52 Logic Controller Action. The
input will go high whenever the Logic
Controller Action [43] Set dig. out. A high
is executed. The input will go low
whenever the Logic Controller Action
[37] Set dig. out. A low is executed.
Output is high when F-02 Operation
Method = [2] Local or when
F-02 Operation Method = [0] Linked to
hand auto at the same time as the
keypad is in Hand mode.
Output is high when F-02 Operation
Method = [1] Remote or [0] Linked to
hand/auto while the keypad is in [Auto]
mode.
[122] No alarm
Output is high when no alarm is present.
[123] Start command
Output is high when there is an active
active
Start command (i.e. via digital input bus
connection or [Hand] or [Auto]), and no
Stop or Start command is active.
[124] Running reverse Output is high when the frequency
converter is running counter clockwise
(the logical product of the status bits
'running' AND 'reverse').
[125] Drive in hand
Output is high when the frequency
mode
converter is in [Hand mode] (as indicated
by the LED light above [Hand]).
[126] Drive in auto
Output is high when the frequency
mode
converter is in [Hand] mode (as indicated
by the LED light above [Auto]).
E-20 Terminal 27 Digital Output
Choices are described under E-2#
E-21 Terminal 29 Digital Output
Choices are described under E-2#
E-24 Function Relay
Array [9]
(Relay 1 [0], Relay 2 [1], Relay 3 [2], Relay 4 [3], Relay 5 [4], Relay
6 [5], Relay 6 [5], Relay 7 [6], Relay 8 [7], Relay 9 [8])
Choices are described under E-2#
E-26 On Delay, Relay
Array [9], (Relay 1 [0], Relay 2 [1], Relay 3 [2], Relay 4 [3], Relay 5
[4], Relay 6 [5], Relay 7 [6], Relay 8 [7], Relay 9 [8])
Range:
0.01 s
[0.01 - 600 s] Enter the delay of the relay cut-in time.
*
The relay will only cut in if the condition
in E-24 Function Relay is uninterrupted
during the specified time. Select one of
available mechanical relays and OPCRLY
Relay Option Module in an array
function. See E-24 Function Relay.
Illustration 3.16 On Delay, Relay
DET-618C
Function:

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents