5-42/END
Remote Errored Frame Seconds Summary
This condition is not an alarm. The system detects that an
Summary
Remote Errored Frame Symbol Period
This condition is not an alarm. The system detects that an
message is issued at the opposing site.
Remote Link Fault
This condition indicates that Ethernet link failure at the opposing site is detected via
the incoming port. This is an alarm regarding IEEE802.3ah, Link OAM.
Procedure 5-29
1.
2.
RX Level
This condition indicates that the receiving level is lower than the threshold level
(between –72 to –94 dBm according to the modulation system and bit rates).
Procedure 5-30
Refer to
GGS-000548-01E
message is issued at the opposing site.
Check if any alarms occur to the equipment or cable connections at n the
opposing site, and if any exist, clear them.
Retrieve the
Current Status
cleared. If the alarm is not cleared, contact NEC for the further maintenance
support.
This step ends the procedure.
5.4 Trouble Shooting Flow
, and check if the
Remote Link Fault
for the procedure.
iPASOLINK EX Advanced: O
CORRECTIVE MAINTENANCE
Errored Frame Seconds
Errored Symbol Period
alarm is
& M
PERATION
AINTENANCE
ETH
ETH
ETH
RF