Modem Maintenance Control (Radio Control) - NEC iPASOLINK EX Advanced Instruction Manual

71-76/81-86 ghz packet radio system
Table of Contents

Advertisement

4-28

4.5 MODEM Maintenance Control (Radio Control)

There are several maintenance control items that can be set during Maintenance
Mode.
The function of each control is as follows; These windows are not enabled if the
system is not in the Maintenance mode.
 ATPC Manual Control
If TX Power Control Mode is selected to ATPC Mode, execute temporally fixing
control to Transmit Power. Select the value range described in ( ) of ATPC Range that
located in the Provisioning Menu (MODEM Function setting -> TX Power Setting)
for Transmit Power. ATPC Manual Control can be selected from either Auto or
Manual. If Transmit Power requires to temporally fixing control, select Manual then
select fixed value (it will be fixed until Auto is selected).
NOTE: ATPC Manual Control is not effective if MTPC Mode is selected.
 TX Mute Control
Despite the equipment configuration setting, forcing the
stop the transmit power of the RF.
If Mute Control is set to OFF, it will cancel the Mute control.
NOTES:
GGS-000548-01E
1.
Mute Control
If
is set to off and
factors, Mute status will remain on.
2.
In case of 1+1 HS configuration, the
Moreover, when forced Mute is controlled in No.1/No.2, Maintenance Mode cannot set
to OFF.
3.
TX Mute
When
is remotely controlled, the setting of the automatic restoration time is
possible. Therefore, TX Mute Release Time should be set.
4.
TX Mute Release Time is set together with TX Mute Control by the item that becomes
effective only when TX Mute Control is done from a higher-level device.
TX Mute Control
Mute OFF
does not work due to uncontrollable
Mute OFF
control does not mute both lines.
iPASOLINK EX Advanced: Operation & Maintenance
CONTROL ITEMS
to ON will