NEC iPASOLINK EX Advanced Instruction Manual page 14

71-76/81-86 ghz packet radio system
Table of Contents

Advertisement

SAFETY GUIDELINE FOR USING HAZARDOUS MICROWAVE RADIATION
Safety distance should be calculated according to the conditions of installation site.
Following show the calculation examples:
 Calculation Example 1 (Front Side of Antenna)
 Calculation Example 2 (Rear Side of Antenna)
The safety distance that is obtained by the conditions above and is below the value
defined by COUNCIL RECOMMENDATIN (1999/519/EC) of 1 mW/cm² is:
iPASOLINK EX Advanced: S
iPASOLINK EX = +18 dBm
Antenna Diameter = 0.6 m
Antenna Gain = 52 dBi
Distance = 9.0 m
Output Power Density : S = 0.982 mW/cm
Limit: Output Power Density S = 10 (W/m
COUNCIL RECOMMENDATION
*:
limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz)
iPASOLINK EX = +18 dBm
Antenna Diameter = 0.6 m
Antenna Gain = –16 dBi
Distance = 0.004 m = 4.0 mm
Output Power Density : S = 0.788 mW/cm
Limit: Output Power Density S = 10 (W/m
COUNCIL RECOMMENDATION
*:
limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz)
Front Side of Antenna (X)  9.0 m
Rear Side of Antenna (Y)  0.004 m = 4.0 mm
I
AFETY
NFORMATION
2
 1 mW/cm
2
2
*
)
= 1 (mW/cm
)
(1999/519/EC) of 12 July 1999 on the
 1 mW/cm
2
2
2
*
)
= 1 (mW/cm
)
(1999/519/EC) of 12 July 1999 on the
- 13 -
2
2
GGS-000544-01E