Pm Items; Monitoring Points - NEC iPASOLINK EX Advanced Instruction Manual

71-76/81-86 ghz packet radio system
Table of Contents

Advertisement

ROUTINE MAINTENANCE
3.3.2.1
Monitor Type
RF BBE
Background Block Error
RF ES
Errored Second
RF SES
Severely Errored Second
RF SEP
Severely Errored Period
RF UAS
Unavailable Second
RF OFS
Out of Frame Second
RX Level (MAX)
RX Level (MIN)
TX Power (MAX)
TX Power (MIN)
TX Modulation
RX Modulation
3.3.2.2
Figure 3-6 Monitoring Point and Range for Line Failure
Facility
RF
iPASOLINK EX Advanced: O

PM Items

Table 3-2 PM Items for MODEM

Monitoring Points

1
Monitoring Item
BBE, ES, SES-, UAS, OFS
& M
PERATION
AINTENANCE
Description
The sum of the background block error.
The cumulative time in which more than
one block error per second was detected.
The cumulative time in which the BER of a
one second period exceeded a set
percentage (30%).
The cumulative time in which the BER of a
one second period exceeded 10E-3.
The cumulative time in which the unit
remained inoperative.
The total number of seconds of Out of
Frame condition, which is generated in 15
minute-blocks. (OFS is applied to the Total
only).
The minimum and maximum reception
level.
The minimum and maximum output power.
Modulating value at radio transmission.
Modulating value at radio reception.
Monitoring Point
Near-End
Spec.
ITU-T G.826
ITU-T G.826
ITU-T G.826
ITU-T G.826
ITU-T G.826
ITU-T G.826
ITU-T G.826
2
Monitoring Range
1
2
GGS-000548-01E
3-7
——
——
——
——
1