NEC iPASOLINK EX Advanced Instruction Manual page 595

71-76/81-86 ghz packet radio system
Table of Contents

Advertisement

3-4
4. Click the Normal Speed / High Speed radio button provided for the
Figure 3-2 Current Metering Option Window (MODEM)
Figure 3-3 Current Metering Option Window (SFP)
Parameter
Refresh Cycle
NOTES:
5. Click the
GGS-000548-01E
option to specify the period of retrieving data:
Cycle
Table 3-1 Current Metering Parameter
Value
Normal Speed (10sec)
High Speed (3sec)
1.
If a parameter indicates the abnormal value, check the Current Status and the
performance monitor (Current/History PMON/RMON Report), and operate the
loopback test to isolate the alarmed sections from the normal sections.
2.
RX LEVEL varies depending on the received RF signal level.
3.
Power Supply voltage varies depending on the length of cable.
Cancel
button on the option window.
This step ends the procedure.
Description
Refreshes measured value every 10 seconds.
Refreshes measured values every 3 seconds.
PASOLINK EX A
I
DVANCED
ROUTINE MAINTENANCE
Refresh
: O
& M
PERATION
AINTENANCE