Chapter 9. Communication

9.1 Modbus Communication

In general, the PT900 flow meter follows the standard Modbus communications
protocol defined by the reference MODBUS APPLICATION PROTOCOL
SPECIFICATION V1.1b
this reference as a guide, the user may use any Modbus master to communicate
with the flow meter.
Two limitations of this implementation are:
The PT900 supports only four of the standard function codes. These are
Read Holding Registers (0x03), Read Input Registers (0x04), Write
Multiple Registers (0x10) and Read File Record (0x14).
The flow meter needs a 15 ms gap between Modbus requests. The prime
objective of the flow meter is to measure flow rate and drive the output, so
the Modbus server has a low priority.

9.2 Modbus Register Map

Table 17 below lists the complete Modbus register map for the PT900.
Register
Register
(in Hex)
(in Dec.)
100
100
256
108
264
118
280
120
288
128
296
130
304
138
312
140
320
148
328
150
336
158
344
300
300
768
304
772
308
776
500
500
1280
502
1282
®
TransPort
PT900 User's Manual
. This specification is available at
Table 17: Modbus Register Map
Access
Description
Level
User
Product Short Tag
User
Product Long Tag
User
eAI1Label
User
eAI2Label
User
eLogName
User
Product Electronical serial number
User
Product fixture serial number
User
Product transducer1 serial number
User
Product transducer2 serial number
User
Product transducer3 serial number
User
Product transducer4 serial number
RO
Main Hardware version
RO
Option Hardware version
RO
Main Software version
User
Global Unit group 1 for Actual Volumetric
User
Global Unit group 2 for Day
Chapter 9. Communication
www.modbus.org
RO/
Format
RW
RW CHAR * 16
RW CHAR * 32
RW CHAR * 16
RW CHAR * 16
RW CHAR * 16
RW CHAR * 16
RW CHAR * 16
RW CHAR * 16
RW CHAR * 16
RW CHAR * 16
RW CHAR * 16
RO CHAR * 8
RO CHAR * 8
RO CHAR * 8
RW INT32
RW INT32