E-1D
General Description
This feature enables selected D
station, to bridge into the busy connection after transmitting a warning tone.
Operating Procedure
To enter a busy connection from a D
1.
Dial the busy station; receive Busy Tone.
2.
Press the EXECUTIVE RIGHT-OF-WAY "OVER" key; the associated LED lights and warning
tone is sent.
3.
The calling station is bridged into a THREE-WAY CALLING [T-2]; the LCD displays:
term
D
Series E
The LCD then displays:
term
D
Series E
Service Conditions
1.
Two burst tones (.08 second) are transmitted upon activation of this feature to alert the
connected parties that an EXECUTIVE RIGHT-OF-WAY call has been bridged into the
connection.
2.
The LCD display on the interrupted party's D
STATION NUMBER DISPLAY - D
3.
EXECUTIVE RIGHT-OF-WAY is denied if the busy station is:
a.) dialing or in a LINE LOCKOUT [L-3] state
b.) receiving a tone
c.) being rung
d.) protected from override via CLASS OF SERVICE - INDIVIDUAL [C-15]
e.) being connected to an Attendant loop
NEAX2400 ICS Business Features and Specifications
NDA-24143, Issue 4
Executive Right-of-Way - D
Executive Right-of-Way - D
term
station users, upon encountering a busy condition at an internal
term
:
Called Party
OVR
(Time Display)
OVERRIDE
(Time Display)
CNF
(Time Display)
CONF
(Time Display)
term
[I-10D] has been programmed in System Data.
term
XXXX
XXXX
term
will give an indication only if INTERMEDIATE
E-1D