Turf Guardian
Leak Detector System (If Equipped)
Operation
The leak detector system is designed to assist in the ear-
ly detection of hydraulic oil system leaks. If the oil level
in the main tank is lowered by 4 to 5 ounces, the level
switch in the leak detection tank will close. After a 1 se-
cond delay, the alarm will sound alerting the operator.
Expansion of oil from the normal heating of the hydraulic
oil during machine operation will cause oil to transfer into
the leak detection tank. The oil is allowed to return to the
main tank when the ignition switch is turned off (see
Figs. 37, 38 and 39).
Electrical System
FLUID LEVEL
COLD
SOLENOID
RETURN
VALVE
OPEN
BEFORE START (oil cold)
FLUID LEVEL
WARM
SOLENOID
RETURN
VALVE
CLOSED
NORMAL OPERATION (oil warm)
FLUID LEVEL
WARM
SOLENOID
RETURN
VALVE
CLOSED
FLOAT DOWN, SWITCH CLOSED
(FLUID LEVEL DOWN 4 TO 5 OUNCES)
Page 5 - - 30
FILLER CAP
NO SOUND
FLOAT RAISED
SWITCH OPEN
Figure 37
NO SOUND
FLOAT RAISED
SWITCH OPEN
Figure 38
WARNING
BUZZER
SOUNDS
LEAK ALERT!
Figure 39
Greensmaster 3250--D
SIGHT
WINDOW