Fuse Block
Fuses can be removed to check continuity. The test me-
ter should read less than 1 ohm.
Fuses supply power to the following (Fig. 8):
1. Fuse F1 (top) (10 ampere) supplies power to the run
and mow relays.
2. Fuse F2 (10 ampere) supplies power to the raise and
lower relays.
3. Fuse F3 (15 ampere) supplies power to terminal B of
the ignition switch.
4. Fuse F4 is available for optional accessories. A max-
imum 15 ampere fuse should be used in this position.
Hour Meter
1. Connect the positive (+) terminal of a 12 VDC source
to the positive terminal of the hour meter.
2. Connect the negative (--) terminal of the voltage
source to the other terminal of the hour meter.
3. The hour meter should move a 1/10 of an hour in six
(6) minutes.
4. Disconnect the voltage source from the hour meter.
Electrical System
Page 5 - - 12