Removal (Fig. 61)
1. Park the machine on a level surface, engage the
parking brake, lower the cutting units and stop the en-
gine. Remove key from the ignition switch.
CAUTION
Before continuing further, read and become fa-
miliar with General Precautions for Removing
and Installing Hydraulic System Components.
2. Label all hydraulic connections and electrical con-
nections for assembly purposes.
3. Disconnect wire harness connectors from manifold
solenoid coils and backlap switch.
IMPORTANT: Before disconnecting any hydraulic
hoses from the hydraulic fittings, make sure each
hose is labeled to ensure it is connected to the cor-
rect manifold fitting/port.
4. Disconnect hose assemblies and their respective O--
rings from hydraulic fittings. Allow hoses to drain into a
suitable container.
5. Remove two (2) cap screws (item 12) that secure the
hydraulic manifold to the frame. Remove manifold as-
sembly from the machine.
IMPORTANT: Before disconnecting any hydraulic
fittings from the hydraulic manifold block, make
sure the position of each fitting is observed and
matchmarked to ensure it is oriented properly on
the manifold.
6. If hydraulic fittings are to be removed from manifold,
mark fitting orientation to allow correct assembly. Re-
move hydraulic fittings and O--rings from manifold. Dis-
card removed O--rings.
Greensmaster 3250--D
Installation (Fig. 61)
1. If fittings were removed from manifold, lubricate and
place new O--rings onto fittings. Install fittings into mani-
fold openings making sure that fitting orientation is as
noted during removal. Tighten fittings (see Hydraulic Fit-
ting Installation in the General Information section of this
chapter).
2. Position manifold assembly to the support frame.
Secure assembly to the frame with two (2) cap screws
(item 12).
3. Using labels placed during manifold removal, lubri-
cate new O--rings and connect hydraulic hoses to mani-
fold. Tighten hose connections (see Hydraulic Hose and
Tube Installation in the General Information section of
this chapter).
4. Connect wire harness connectors to manifold sole-
noid coils and backlap switch.
5. Make sure that hydraulic tank is at correct level.
6. Start machine. Run machine at idle for 3 to 5 minutes
to circulate hydraulic fluid and remove any air trapped in
the system. Stop machine and recheck hydraulic tank
level.
Page 4 - - 89
Hydraulic System

Hide quick links: