Automatic Point-Type Fire Detectors; Series Iq8Quad Fire Detectors - Honeywell ESSER FACP Technical Information

Table of Contents

Advertisement

Periphery components for ESSER FACP
5

Automatic point-type fire detectors

5.1

Series IQ8Quad fire detectors

Automatic point-type smoke/heat detectors with integrated loop isolator with maximum reliability for objects with
average to high value concentration for connection to the esserbus
alarm control panels.
Features
Designed for optimal operation on FACP Compact, IQ8Control and FlexES Control
With multisensor fire detectors for the detection of all types of fires, even under the most difficult operating
conditions.
Detector with and without loop isolator
Wiring in loop and spur combination
Maximum number of detectors with cable lengths of up to 3,500 m (I-Y (St) Yn x 2 x 0.8 mm or similar)
Up to 127 detectors and detector zones per loop installation
Up to 32 detectors per zone
Free wiring of display and control elements with software-based function assignment
Optional automatic or interactive detector address allocation
Fixed address assignment of detector location, even after detectors have been replaced or added
Localization of wire breaks and short circuits on loop
Detector-LED used as alarm indicator and as an indicator for detectors in service
Adaptation to changing operating conditions
Dedicated LED for indicating operation (green LED)
Disconnection of individual detectors, detector zones and detection areas
Disconnection of individual sensors or several sensors at once within a multisensor fire detector; either
manually or depending on programmed time of the day
Compensation of changing levels of air pressure, humidity, smoke concentration according to the double
chamber principle
Electronic compensation of long-term influences like aging or pollution
Constant alarm sensitivity of multisensor fire detector for all types of fire
Large signal to noise ratio due to the special design of the sensors and the electronics to suppress
electromagnetic interference
Reliable false alarm suppression high immunity against false alarms by means of timed evaluation of
different sensor criteria
Signal patterns not typical for fires are eliminated by using special filter algorithms
Automatic self-monitoring of detector electronics
Continuous loop monitoring even during short-circuits through isolating the relevant segment
Automatic monitoring of all sensors to guarantee operational capacity and correct condition
Short-circuit and wire break tolerant
Alarm decision directly in the detector and forwarding of the alarms even if concentrated processing nodes fail
Fail-safe circuit activated if communication fails
Maintenance
Automatic maintenance request
Heat detector identification through a black circle on the light transmission plate
Multisensor gas detector identification through a golden loop on the circle transmission plate
Operating time-, alarm- and fault counter in each detector
Automatic, cyclic loop check
Complete status interrogation from the control panel
Operating data from all detectors in a network is collected using the service PC and via the fieldbus and
control panel interface, even without the FACP
Comprehensive range of accessories
Standard detector base and relay base
Base adapter for ceiling mounting
Kit for suspended ceiling mounting
Dust cover for fire detector or detector base
An excellent overview of the IQ8Quad fire detectors, including possible applications is provided by the
app: "IQ8Quad - Which fire detector for which application?"
The app is available in Google Play and the App Store.
12
®
/esserbus
®
PLus loop of the ESSER fire
TI 798960.GB0 / 04.20